
DEEP N BLUE · SUBOTICA
Diving tools
BETA 1.3.4.1 · MV Plan source · Interactive calculations and diving physics — with explanations of formulas, units and assumptions.
EANx · O₂
MOD calculator
MOD – maximum operating depth for the specified mixture and selected oxygen partial pressure limit (ppO₂).
MOD = (ppO₂ limit / FO₂ − P₀) × kP₀ = surface pressure; k ≈ 9.90 m/bar in saltwater or 10.19 m/bar in freshwater (MV Plan reference).Before an actual dive, gas must be analysed and correctly labelled. MOD is an oxygen limit — it does not confirm that the depth is safe according to other criteria.
NITROGEN · EQUIVALENT DEPTH
EAD calculator
EAD – the equivalent depth when breathing air at the same nitrogen partial pressure as the specified EANx at the selected depth.
EAD = [(FN₂ / 0.79) × (P₀ + d/k) − P₀] × kFN₂ = 1 − FO₂. Applies to EANx as an O₂ + N₂ mixture, without helium. This is not a decompression schedule.OPEN CIRCUIT · GAS CONSUMPTION PLANNER
Gas Planner
Estimated gas consumption by dive phase, with primary and additional (stage) cylinders. This is not a decompression or emergency/rock-bottom planner.
SAC is expressed in bar/min and depends on the reference cylinder volume; RMV is expressed in L/min and is more practical for multiple cylinder sizes. The consumption factor multiplies consumption; it does not calculate the required gas reserve.
Cylinders and gases
Dive phases
Calculation result
For each phase, enter the average depth for consumption, the maximum depth for the ppO₂ check, the time and the cylinder being breathed from. No decompression simulation.
This module does not determine minimum gas for safe return, gas sharing, penetration, decompression or reserves for equipment failures. An appropriate expert plan is required, especially in overhead environments, with multiple-gas equipment or complex profiles.
INTERACTIVE CLASSROOM
Dive Science
Move the depth slider to see how ambient pressure, gas volume and partial pressures change.
P × V = constant (Boyle, at constant temperature)pp(gas) = F(gas) × P(absolute) (Dalton)These are simplified educational models, not an assessment of actual barotrauma or toxicity risk.DECOMPRESSION · SOFTWARE-TESTED INTEGRATION
DECO BETA — MV Plan ZH-L16C + GF
Bühlmann ZH-L16C model with GF, based on the original MV Plan 2.0.35-dev core. Displays the stop schedule, ascent time, gases and profile, with the scope of software tests and limitations clearly stated.
Test details and limitations
Original MV Plan core: 6,116/6,116 individual checks. DNB adapter: 231/231 compatible scenarios with identical stops, 9/9 stop schedules from MV Plan web profiles and 8/8 available total times using an empirical rounding rule. MOD, EAD, gas and Dive Science: 140,054 numerical, boundary and structural checks.
These are software tests, not medical validation. Not all possible profiles have been tested. One reference case with a manually specified switch to EAN50 at 22 m was excluded because it exceeds our ppO₂ limit of 1.6 bar (MOD 21 m). Repetitive dives and CCR are not implemented. Differences in configuration, version and rounding may change the result.
Simulation result
Enter the parameters, acknowledge the limitations and run the simulation.
Illustrative depth profile
Decompression / safety stops
| Depth | Stop duration | Gas |
|---|
Estimated gas consumption in the model
Consumption is based on MV Plan segment calculations using the specified RMV and cylinder capacities; actual gas availability and reserve scenarios have not been verified. This is not an operational gas plan.
How does the reference model calculate?
Schreiner + Haldane · 16 tissues · N₂/HeGF ceiling: P = (P tissue − a×GF) / (GF/b + 1−GF)ZH-L16C coefficients (OSTC/DecoTengu variant); idealized open circuit, dry gas except for water vapour at 0.0627 bar.Limitations and sources: DecoTengu — equations and coefficients · Subsurface — tested comparison tool · MV-Plan — another planner. The DNB adapter uses MV Plan 2.0.35-dev and has undergone documented regression comparisons. Software versions, total time rounding, gas limits and user settings may yield different results; verify every actual plan independently.
Calculation algorithm source code in the installation ZIP: assets/vendor/mvplan/. AGPL-3.0-or-later licence; see LICENSE in the plugin.
Glossary of abbreviations and symbols (open)
- EANx
- Enriched Air Nitrox – oxygen-enriched air; “x” indicates the O₂ percentage (e.g. EAN32).
- MOD
- Maximum Operating Depth – maximum operating depth at the specified ppO₂ limit.
- EAD
- Equivalent Air Depth – equivalent air depth based on ppN₂.
- FO₂ / FN₂
- Fraction of Oxygen / Nitrogen – volume fraction of oxygen / nitrogen in the gas mixture.
- ppO₂ / ppN₂
- Partial Pressure of Oxygen / Nitrogen – partial pressure of oxygen / nitrogen.
- SAC
- Surface Air Consumption – cylinder pressure drop converted to surface conditions (bar/min).
- RMV
- Respiratory Minute Volume – volumetric gas consumption at the surface (L/min).
- OC / CCR
- Open Circuit / Closed Circuit Rebreather – open-circuit breathing system / closed-circuit rebreather.
- GF Low / High
- Gradient Factors – factors controlling permissible supersaturation in the Bühlmann model.
- ZHL-16C
- Bühlmann model with 16 theoretical tissue compartments; “C” denotes the model coefficient set.
- Stage / bailout
- Additional gas cylinder / reserve gas for emergencies.
English calculator integration: corresponding source and translation audit (AGPL-3.0-or-later)

